Use PT Series Part Number Crossover Tool to convert from 100, 200, 300 and 615 Series transmitters to new PT Series transmitters.
Use PT Series Part Number Crossover Tool to convert from 100, 200, 300 and 615 Series transmitters to new PT Series transmitters.
Part Number |
Description |
Clamp Size |
Housing Material |
Full Scale Best Fit Straight Line (BFSL) Accuracy (±) |
Pressure Range |
|---|---|---|---|---|---|
| 110-12-4-615-1-13-1-14 | N/A 1-1/2" Sanitary Clamp, ±0.25% Accuracy (Best Fit Straight Line (BFSL), -30 inHg to 100 psig, 4 to 20 mA Output Sanitary Transducer with DIN EN 175301-803 Form A Connection with ISO 4400 1/2 in. National Pipe Thread (NPT) Conduit | N/A 1-1/2 in | N/A 316 Stainless Steel | N/A 0.125 %0.25 % | N/A -30 inHg to 100 psig |
| 110-12-4-615-1-34-1-25 | N/A 1-1/2" Sanitary Clamp, ±0.25% Accuracy (Best Fit Straight Line (BFSL), 0 to 5 psig, 4 to 20 mA Output Sanitary Transducer with M12 x 1 (4-Pin) | N/A 1-1/2 in | N/A 316 Stainless Steel | N/A 0.125 %0.25 % | N/A 0 to 5 psig |
| 110-12-4-615-1-34-1-36 | N/A 1-1/2" Sanitary Clamp, ±0.25% Accuracy (Best Fit Straight Line (BFSL), 0 to 5 psig, 4 to 20 mA Output Sanitary Transducer with 36" Integral Cable | N/A 1-1/2 in | N/A 316 Stainless Steel | N/A 0.125 %0.25 % | N/A 0 to 5 psig |
| 110-12-4-615-1-40-1-8 | N/A 1-1/2" Sanitary Clamp, ±0.25% Accuracy (Best Fit Straight Line (BFSL), 0 to 15 psig, 4 to 20 mA Output Sanitary Transducer with DIN EN 175301-803 Form A | N/A 1-1/2 in | N/A 316 Stainless Steel | N/A 0.125 %0.25 % | N/A 0 to 15 psig |
| 110-12-4-615-1-46-1-1 | N/A 1-1/2" Sanitary Clamp, ±0.25% Accuracy (Best Fit Straight Line (BFSL), 0 to 60 psig, 4 to 20 mA Output Sanitary Transducer with DIN EN 175301-803 Form A (36" Cable Attached) | N/A 1-1/2 in | N/A 316 Stainless Steel | N/A 0.125 %0.25 % | N/A 0 to 60 psig |
| 110-12-4-615-1-49-1-25 | N/A 1-1/2" Sanitary Clamp, ±0.25% Accuracy (Best Fit Straight Line (BFSL), 0 to 100 psig, 4 to 20 mA Output Sanitary Transducer with M12 x 1 (4-Pin) | N/A 1-1/2 in | N/A 316 Stainless Steel | N/A 0.125 %0.25 % | N/A 0 to 100 psig |
| 110-12-4-615-1-52-1-1 | N/A 1-1/2" Sanitary Clamp, ±0.25% Accuracy (Best Fit Straight Line (BFSL), 0 to 150 psig, 4 to 20 mA Output Sanitary Transducer with DIN EN 175301-803 Form A (36" Cable Attached) | N/A 1-1/2 in | N/A 316 Stainless Steel | N/A 0.125 %0.25 % | N/A 0 to 150 psig |
| 110-12-4-615-1-55-1-8 | N/A 1-1/2" Sanitary Clamp, ±0.25% Accuracy (Best Fit Straight Line (BFSL), 0 to 160 psig, 4 to 20 mA Output Sanitary Transducer with DIN EN 175301-803 Form A | N/A 1-1/2 in | N/A 316 Stainless Steel | N/A 0.125 %0.25 % | N/A 0 to 160 psig |
| 110-12-4-615-1-58-1-8 | N/A 1-1/2" Sanitary Clamp, ±0.25% Accuracy (Best Fit Straight Line (BFSL), 0 to 200 psig, 4 to 20 mA Output Sanitary Transducer with DIN EN 175301-803 Form A | N/A 1-1/2 in | N/A 316 Stainless Steel | N/A 0.125 %0.25 % | N/A 0 to 200 psig |
| 110-12-4-615-1-61-1-25 | N/A 1-1/2" Sanitary Clamp, ±0.25% Accuracy (Best Fit Straight Line (BFSL), 0 to 300 psig, 4 to 20 mA Output Sanitary Transducer with M12 x 1 (4-Pin) | N/A 1-1/2 in | N/A 316 Stainless Steel | N/A 0.125 %0.25 % | N/A 0 to 300 psig |
| 110-12-4-615-1-61-1-36-20 | N/A 1-1/2" Sanitary Clamp, ±0.25% Accuracy (Best Fit Straight Line (BFSL), 0 to 300 psig, 4 to 20 mA Output Sanitary Transducer with 20 ft Integral Cable | N/A 1-1/2 in | N/A 316 Stainless Steel | N/A 0.125 %0.25 % | N/A 0 to 300 psig |
| 110-16-4-615-1-40-1-1 | N/A 2" Sanitary Clamp, ±0.25% Accuracy (Best Fit Straight Line (BFSL), 0 to 15 psig, 4 to 20 mA Output Sanitary Transducer with DIN EN 175301-803 Form A (36" Cable Attached) | N/A 2 in | N/A 316 Stainless Steel | N/A 0.125 %0.25 % | N/A 0 to 15 psig |
| 110-16-4-615-1-58-1-36-20 | N/A 2" Sanitary Clamp, ±0.25% Accuracy (Best Fit Straight Line (BFSL), 0 to 200 psig, 4 to 20 mA Output Sanitary Transducer with 20 ft Integral Cable | N/A 2 in | N/A 316 Stainless Steel | N/A 0.125 %0.25 % | N/A 0 to 200 psig |
| 110-16-4-615-1-61-1-1 | N/A 2" Sanitary Clamp, ±0.25% Accuracy (Best Fit Straight Line (BFSL), 0 to 300 psig, 4 to 20 mA Output Sanitary Transducer with DIN EN 175301-803 Form A (36" Cable Attached) | N/A 2 in | N/A 316 Stainless Steel | N/A 0.125 %0.25 % | N/A 0 to 300 psig |